Environmental Sanitation Engineering ›› 2019, Vol. 27 ›› Issue (6): 68-71.

Previous Articles     Next Articles

Experimental Study on the Leachate from Waste Incineration Plant Treated by Anaerobic Biological Filter

Jiang Yabin, Wei Xinqing, Zhang Gensheng, Pu Hongxia   

  1. Tianjin JC Environmental Services Co. Ltd.
  • Online:2019-12-26 Published:2020-01-03

Abstract: The leachate from waste incineration plant was treated by anaerobic biological filter. The inoculated sludge was digestion sludge which came from a Continuous Stirred-Tank Reactor(CSTR). The operating temperature was kept at (37±2) ℃. After biofilm were completly growing well, the reactor operated steadily and continuously for nearly six months. During this period, the treatment effect of the reactor on leachate was studied by monitoring COD, NH3-N, TN, pH, VFA, TIC, VAF/TIC, daily biogas production and CH4 content. The results showed that the removal efficiency of organic pollutants in leachate by anaerobic biological filter was very high. When the inlet COD concentration was 49 000~82 000 mg/L and the outlet COD concentration was 3 000~8 000 mg/L, the removal rate of COD reached over 90%; During the operation of the reactor, the TIC was nearly 10 000 mg/L, and the VFA/TIC was basically maintained at 0.2~0.5, which belonged to the appropriate range of anaerobic reactors. Ammonification was significantly, and NH3-N/TN of inlet(40%~70%) was obviously lower than that of outlet (85%~99%); Gas production efficiency was high, the daily biogas production could reach 300~400 L, CH4 content was nearly 70%.

No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . Optimization Study on Effect Evaluation Index for Source Separation of Municipal Solid Waste Based on F-measure   [J]. Environmental Sanitation Engineering, 2018, 26(3): 1 -3 .
[2] . Exploration and Research on Improving the Classification Effect of Domestic Garbage in Guangzhou   [J]. Environmental Sanitation Engineering, 2018, 26(3): 4 -7 .
[3] . Municipal Sewage Sludge Co-firing in Waste Incineration Power Plant: A Case Study of Hengyang City   [J]. Environmental Sanitation Engineering, 2018, 26(3): 14 -17 .
[4] . Study on Influencing Factors of Municipal Solid Waste Heating Value in Taiyuan   [J]. Environmental Sanitation Engineering, 2018, 26(3): 29 -32 .
[5] . Inhibition Concentration and Elimination Method of Ammonia Nitrogen in Anaerobic Digestion Process   [J]. Environmental Sanitation Engineering, 2018, 26(3): 33 -35 .
[6] . Operation Management Acceptance and Detection Analysis of Closed Waste Cleaning Stations in Beijing   [J]. Environmental Sanitation Engineering, 2018, 26(3): 49 -51 .
[7] . Discussion on Optimum Design of UASB Reactor for Leachate   [J]. Environmental Sanitation Engineering, 2018, 26(3): 63 -67 .
[8] . Engineering Design of Construction Waste Reclamation in Daxing District of Beijing   [J]. Environmental Sanitation Engineering, 2018, 26(3): 71 -74 .
[9] . Technology Upgrading and Architectural Design on Relieving NIMBY Problem of MSW Incineration Power Plant in#br# Mingzhou of Ningbo   [J]. Environmental Sanitation Engineering, 2018, 26(3): 75 -77 .
[10] . Types and Application Conditions of Municipal Solid Waste Waterway Transportation at Home and Abroad   [J]. Environmental Sanitation Engineering, 2018, 26(3): 78 -83 .
Copyright © Environmental Sanitation Engineering
Address: 107#, Weidi Road, Tianjin, P.R.C.    Postcode: 300201
Telephone: 022-28365069   Fax: 022-28365080 E-mail: csglwyjs10@tj.gov.cn
Supported by:Beijing Magtech