环境卫生工程 ›› 2026, Vol. 34 ›› Issue (5): 79-83.doi: 10.19841/j.cnki.hjwsgc.2026.05.010

• 有机固废生物处理与高值化利用 • 上一篇    下一篇

上海川东农场鸡粪处理中心工程设计与实践

劳德坤,王大鹏,张 强,陈 克   

  1. 建设综合勘察研究设计院有限公司
  • 出版日期:2026-10-29 发布日期:2026-10-29

Design and Practice of the Chicken Manure Treatment Center Project in Shanghai Chuandong Farm

Lao Dekun, Wang Dapeng, Zhang Qiang, Chen Ke   

  1. Comprehensive Institute of Geotechnical Investigation and Surveying Co. Ltd.
  • Online:2026-10-29 Published:2026-10-29

摘要: 上海川东农场鸡粪处理中心鸡粪处理规模为165.0 t/d,设计采用槽式好氧堆肥模式,堆肥产品有机质、总养分及重金属含量的限值指标要求达到NY/T 525—2021有机肥料标准。鸡粪处理中心从设计上采用新型防腐、多孔砖分段曝气、多方联动自动控制等新技术,解决了好氧发酵钢结构防腐、发酵槽分段曝气以及堆体氧气不足等问题。试运行评估结果表明:发酵槽升温段、高温段、降温段每立方米堆体曝气量分别为0.1~0.2、0.2~0.3、0.1~0.2 m3/min,堆体含氧量>8%,发酵堆体NH3含量<80 mg/m3,均满足设计要求。发酵厂房钢结构初步附着力、密封性和防腐性能良好,试块经过5%中性连续喷雾盐雾48 h后,未发现生锈、白斑和腐蚀现象。

关键词: 鸡粪处理, 好氧发酵, 防腐涂层, 分段曝气

Abstract: The chicken manure treatment center of Shanghai Chuandong farm has a treatment capacity of 165.0 t/d, and adopts the trough-type aerobic composting mode in design. The limit indicators for organic matter content, total nutrient content and heavy metal content of the compost product are required to meet the standard of NY/T 525—2021 Organic Fertilizer. Novel technologies including novel anti-corrosion, stepped aeration with porous bricks, and multi-linked automatic control are adopted in the design of the chicken manure treatment center, which solves the problems of anti-corrosion of the steel structure for aerobic fermentation, stepped aeration of fermentation troughs, and insufficient oxygen supply to the compost body. The evaluation results of the trial operation showed that the aeration rates per cubic meter of compost body in the temperature-increasing stage, high-temperature stage and cooling-down stage of the fermentation trough were 0.1~0.2 m3/min, 0.2~0.3 m3/min and 0.1~0.2 m3/min, respectively. The oxygen content of the compost body was higher than 8%, and the NH? content in the fermentation compost body was lower than 80 mg/m3, all of which met the design requirements. The initial adhesion, sealing performance and anti-corrosion performance of the steel structure of the fermentation plant were good. After the test specimens underwent 48 hours of continuous neutral salt spray testing with 5% concentration, no rust, white spots or corrosion phenomena were observed.

Key words: chicken manure treatment, aerobic fermentation, antiseptic coating, segmented aeration