厌氧生物滤池处理焚烧厂垃圾渗沥液试验研究

江亚斌,魏新庆,张根升,蒲红霞   

  1. 天津建昌环保股份有限公司
  • 出版日期:2019-12-26 发布日期:2020-01-03

Experimental Study on the Leachate from Waste Incineration Plant Treated by Anaerobic Biological Filter

Jiang Yabin, Wei Xinqing, Zhang Gensheng, Pu Hongxia   

  1. Tianjin JC Environmental Services Co. Ltd.
  • Online:2019-12-26 Published:2020-01-03

摘要: 采用厌氧生物滤池对焚烧厂垃圾渗沥液进行处理,接种污泥为CSTR消化污泥,在(37±2)℃条件下完成挂膜后,反应器连续稳定运行近6个月。期间通过对COD、NH3-N、TN、pH、VFA、TIC、VAF/TIC、日产气量及CH4含量等指标的监测,研究反应器对渗沥液的处理效果。结果表明,厌氧生物滤池对渗沥液中有机污染物的去除率很高,当进水COD浓度为49 000~82 000 mg/L,出水COD浓度为3 000~8 000 mg/L,COD去除率基本维持在90%以上;系统运行期间TIC可达10 000 mg/L左右,VFA/TIC基本维持在0.2~0.5,属于厌氧反应器的适宜范围;氨化作用显著,进水NH3-N/TN(40%~70%)明显低于出水NH3-N/TN(85%~99%);产气效率较高,日产气量可达300~400 L,CH4含量约70%。

Abstract: The leachate from waste incineration plant was treated by anaerobic biological filter. The inoculated sludge was digestion sludge which came from a Continuous Stirred-Tank Reactor(CSTR). The operating temperature was kept at (37±2) ℃. After biofilm were completly growing well, the reactor operated steadily and continuously for nearly six months. During this period, the treatment effect of the reactor on leachate was studied by monitoring COD, NH3-N, TN, pH, VFA, TIC, VAF/TIC, daily biogas production and CH4 content. The results showed that the removal efficiency of organic pollutants in leachate by anaerobic biological filter was very high. When the inlet COD concentration was 49 000~82 000 mg/L and the outlet COD concentration was 3 000~8 000 mg/L, the removal rate of COD reached over 90%; During the operation of the reactor, the TIC was nearly 10 000 mg/L, and the VFA/TIC was basically maintained at 0.2~0.5, which belonged to the appropriate range of anaerobic reactors. Ammonification was significantly, and NH3-N/TN of inlet(40%~70%) was obviously lower than that of outlet (85%~99%); Gas production efficiency was high, the daily biogas production could reach 300~400 L, CH4 content was nearly 70%.

No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 杨 龑 陈海滨 杨 禹 等. 基于F-measure的生活垃圾分类效果评价指标优化研究[J]. 环境卫生工程, 2018, 26(3): 1 -3 .
[2] 陈美珠. 广州市提高生活垃圾分类效果的探索与研究[J]. 环境卫生工程, 2018, 26(3): 4 -7 .
[3] 刘志永 郑泽华. 生活垃圾焚烧发电协同处置市政污泥技术研究——以衡阳市为例[J]. 环境卫生工程, 2018, 26(3): 14 -17 .
[4] 鲁晓菊 杨 迪 姚俊花. 太原市生活垃圾热值影响因素研究[J]. 环境卫生工程, 2018, 26(3): 29 -32 .
[5] 王占磊 陈 丽 刘兰英 等. 厌氧消化过程中氨氮的抑制浓度和消除方法[J]. 环境卫生工程, 2018, 26(3): 33 -35 .
[6] 胡昌夏 徐利奇 卫 革. 北京市密闭式清洁站运行管理验收及检测分析[J]. 环境卫生工程, 2018, 26(3): 49 -51 .
[7] 喻本宏 余明锐. 应用于渗沥液的UASB反应器的优化设计探讨[J]. 环境卫生工程, 2018, 26(3): 63 -67 .
[8] 王凯楠. 北京市大兴区建筑垃圾资源化工程设计[J]. 环境卫生工程, 2018, 26(3): 71 -74 .
[9] 毕 蕾 谭翊莅 董亚楠. 宁波明州生活垃圾焚烧发电厂规避邻避问题的技术升级和建筑设计[J]. 环境卫生工程, 2018, 26(3): 75 -77 .
[10] 关春雨. 国内外垃圾水运类型与适用条件分析[J]. 环境卫生工程, 2018, 26(3): 78 -83 .
版权所有 © 天津市城市管理研究中心
津ICP备2022007900号-1   津公网安备 12010302000952号   中央网信办违法和不良信息举报中心
地址:天津市河西区围堤道107号    邮政编码: 300201
电话: 022-28365069 传真: 022-28365080 E-mail: csglwyjs10@tj.gov.cn
本系统由北京玛格泰克科技发展有限公司设计开发