注氧稳定化预处理技术在生活垃圾卫生填埋场存量垃圾开挖中的应用

梁智飞,祝雄涛   

  1. 广州市城建规划设计院有限公司
  • 出版日期:2024-12-27 发布日期:2024-12-27

Application of Oxygen Injection Stabilization Pretreatment Technology in Excavation of Stockpiled Waste from Domestic Waste Sanitary Landfill

LIANG Zhifei, ZHU Xiongtao   

  1. Guangzhou Urban Construction Planning & Design Co. Ltd.
  • Online:2024-12-27 Published:2024-12-27

摘要: 以华南地区某生活垃圾卫生填埋场存量垃圾开挖项目为分析对象,根据填埋场水文地质、防渗系统情况和存量垃圾的理化特性,采用分阶段、分区域、逐层方式设计模块化、自动化的注氧稳定化预处理系统,使垃圾开挖单元形成好氧生物反应器,提升从厌氧状态至好氧状态的转化速度,在短周期(35 d内)达到稳定化的目标,便于存量垃圾的后续开挖与运输。通过注氧稳定化预处理的监测与控制手段,使垃圾堆体内甲烷气体浓度低于3%,开挖单元自然排气中臭气浓度限值满足GB 14554—1993恶臭污染物排放标准的要求,单层垃圾堆体内渗滤液水头小于40 cm;同时存量垃圾的易降解物质大量降解,BDM指标对比注氧稳定化预处理前下降幅度较大。

关键词: 生活垃圾卫生填埋场, 存量垃圾, 注氧稳定化预处理, 稳定化单元, 垃圾开挖

Abstract: Taking the stockpiled waste excavation project of a domestic waste sanitary landfill in South China as the analysis object, according to the hydrogeology of the landfill, the anti-seepage system and the physicochemical characteristics of the stockpiled waste, a modular and automated oxygen injection stabilization pretreatment system was designed in a phased, zoned, and layer-by-layer manner. This could enable the waste excavation unit to form an aerobic bioreactor and increase the conversion speed from anaerobic state to aerobic state. The stabilization goal could be achieved within a short period (less than 35 days), which is convenient for the subsequent excavation and transportation of stockpiled waste. Through the monitoring and control means of oxygen injection stabilization pretreatment, the concentration of methane gas in the waste pile was less than 3%, the odor concentration limit in the natural exhaust of the excavation unit met the requirements of GB 14554—1993 Emission Standards for Odor Pollutants, and the leachate head in a single-layer waste pile was less than 40 cm. At the same time, a large amount of degradable substances in the stockpiled waste were degraded, and the BDM index had a large drop compared with that before oxygen injection stabilization pretreatment.

Key words: domestic waste sanitary landfill, stockpiled waste, oxygen injection stabilization pretreatment, stabilization unit, waste excavation

[1] 葛恩燕, 胡 超. 生活垃圾填埋场开采筛分处置技术研究——以卧旗山垃圾填埋场为例[J]. 环境卫生工程, 2022, 30(5): 88-93.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 张福泉. 通辽市某垃圾填埋场地下水水质现状评价[J]. 环境卫生工程, 2018, 26(3): 36 -38 .
[2] 袁 松 黄丹丹 段怡彤. 生活垃圾转运站臭气属性特征及不同除臭工艺效果分析[J]. 环境卫生工程, 2018, 26(3): 56 -58 .
[3] 刘 霄. 垃圾焚烧发电厂汽水管道应力分析和支吊架设计的优化[J]. 环境卫生工程, 2018, 26(3): 59 -62 .
[4] 白贤祥 张玉刚. 生活垃圾焚烧厂余热锅炉水冷壁高温腐蚀治理研究[J]. 环境卫生工程, 2018, 26(3): 68 -70 .
[5] 杨森林 王科林 吴善荀 等. 餐厨垃圾处置设施规划中对餐厨垃圾产生量的预测[J]. 环境卫生工程, 2018, 26(3): 87 -90 .
[6] 郑苇刘淑玲李波靳俊平. 禽畜干清粪工艺产生鲜粪的厌氧消化处理技术探讨[J]. 环境卫生工程, 2018, 26(1): 5 -8 .
[7] 王晓燕胡昌夏孙晨阳徐利奇. CJ/T 280—2008塑料垃圾桶通用技术条件标准实施情况解析[J]. 环境卫生工程, 2018, 26(1): 63 -65 .
[8] 朱志军刘文涛. 北京市餐厨垃圾现状调查及减量化路径研究[J]. 环境卫生工程, 2018, 26(1): 66 -69 .
[9] 何晟洪毅干磊. 苏州市建筑垃圾智能化监管平台设计[J]. 环境卫生工程, 2018, 26(1): 77 -79 .
[10] 梁永宽李逸民. 填埋气掺烧天然气发电收益估算——以荣昌填埋气发电厂为例[J]. 环境卫生工程, 2018, 26(1): 80 -83 .
版权所有 © 天津市城市管理研究中心
津ICP备2022007900号-1   津公网安备 12010302000952号   中央网信办违法和不良信息举报中心
地址:天津市河西区围堤道107号    邮政编码: 300201
电话: 022-28365069 传真: 022-28365080 E-mail: csglwyjs10@tj.gov.cn
本系统由北京玛格泰克科技发展有限公司设计开发